Home > Product > Generator Sets > Diesel Generator Sets

Cummins 110kw Diesel Gensets

Cummins Diesel Genset SCDG-110KW Ø Standard Configuration  Engine(Cummins 6BTAA5.9-G2)  Radiator 50℃ max, fans are driven by belt, with safety guard  24V charge alternator  Alternator: single bearing alternator IP23, insulation class H/H  Absorber  Dry type air filter, fuel filter, oil...

Send InquiryChat Now
Product Details

Cummins Diesel Genset SCDG-110KW


Code

SCDG-110KW

Rated Power(50HZ)

110KW/138KVA

Standby Power(50HZ)

120KW/150KVA


Ø Standard Configuration

 Engine(Cummins 6BTAA5.9-G2)

 Radiator 50℃ max, fans are driven by belt, with safety guard

 24V charge alternator

 Alternator: single bearing alternator IP23, insulation class H/H

 Absorber

 Dry type air filter, fuel filter, oil filter

 Main line circuit breaker

 Standard control panel

 Two12V batteries, rack and cable

 Ripple flex exhaust pipe, exhaust siphon, flange, muffler

 User manual

Ø Generator Ratings



Voltage


HZ


Phase


P.F

(COS¢)


Standby Amps

Standby

Ratings

(KW/KVA)

Prime

Ratings

(KW/KVA)

254/440

50

3

0.8

196

120/150

110/138

240/415

50

3

0.8

208

120/150

110/138

230/400

50

3

0.8

216

120/150

110/138

220/380

50

3

0.8

227

120/150

110/138


Prime Power (PRP): Prime power is available for an unlimited number of annual hours in variable load application, in accordance with GB/T2820-97(eqvISO8528); A 10% overload capability is available for a period of 1 hour within a 12-hour period of operation.

Standby Power Rating (ESP): The standby power rating is applicable for supplying emergency power for the duration of a utility power interruption. No overload, utility parallel or negotiated outage operation capability is available at this rating.

Ø Engine Data


1. Basic parameter

Engine Model

Cummins 6BTAA5.9-G2

Engine Features

In-line, 6 Cylinders, Four-stroke

Rated Power

120KW /1500rpm

Standby Power

132KW /1500rpm

Displacement

5.9L

Bore*Stroke

102*120 mm

Compression Ratio

17.3:1

Mode of Speed Regulation

Electronic

Net Weight

405 KG

Over Dimension

1110*750*988 mm

2. Exhaust Air System

Exhaust air capacity

19.7 m?/min

Exhaust air temperature

540 ℃

Max. exhaust back pressure

10 kPa

3. Air Intake System

Air Intake Type

Turbocharged, air-air cooling

Max. Air Intake Pressure

6.1 kPa

Air Combustion Capacity

7.2 m³/min

Air flow

190 m³/min

4. Fuel System

Fuel Consumption

208g.kWh or 27.8L/h (100% loading)

5. Lubrication System

Oil Capacity

16.4 L

Oil Consumption

≤4g/KW.h

Oil Pan Capacity

12.3-14.2 L

Rated Speed Oil Pressure

345 kPa

6. Cooling System

Cooling Type

Closed Water-Cooling

Total Cooling Liquid Capacity

29 L

Thermostat Working Temperature

82-95 ℃

Max. Water Temperature

104 ℃


Ø Alternator Data


Brand

Stamford UCI274E

Number of Phase

3

Connecting Type

3 Phase and 4 Wires, “Y” type connecting

Number of Bearing

1

Power Factor

0.8

Protection Grade

IP23

Altitude

≤1000m

Exciter Type

Brushless, self-exciting

Insulation Class,

Temperature Rise

H/H

Telephone Influence Factor (TIF)

<50

THF

<2%

Alternator Capacity

140KVA

Alternator Efficiencies

91.7%


Services.png

Hot Tags: cummins 110kw diesel gensets, manufacturers, suppliers, factory, customized, cheap, buy discount, low price