Extend

Several cases of white smoke from diesel generator sets

White smoke is divided into gray smoke and water vapor white smoke.


1. Gray smoke, the fuel entering the cylinder is poorly burned, and some of the fuel is evaporated into gas steam. With the exhaust gas removal, the main reasons are as follows:

The injector needle is stuck in the open position

Injector injection poor atomization三柴图片.png

The oil supply angle is too small

Tight pressure is seriously insufficient

Operating temperature is too low

Thermostat damage

Coolant temperature sensor is damaged

Preheating system is faulty


2, water vapor white smoke, moisture into the combustion chamber by heat gasification, the main reasons are as follows:

There is water in the fuel

Cylinder head burned

Crack in the cylinder or cylinder head


Failure Analysis of Diesel Engine Injector Melting