The diesel generator set consists of a diesel engine, an AC synchronous generator, a control panel, and a chassis, a coupling, a radiator, a fuel tank, and the like. Some also have a muffler and a cover. Direct connection between the shafts of diesel engines and generators. Usually, a flywheel is also mounted on the main shaft to increase the smoothness of the operation. Diesel generator sets are generally assembled by the manufacturer as a complete set of units; others are based on the electrical load and its characteristics, after determining the capacity and number of generators, and then selecting the diesel engine that drives the generator. The fuel system and the starting air system can be configured individually or in multiple units.

Sanchai Diesel Genset SCDG-420


Code

SCDG-420

Rated Power(50HZ)

420KW/525KVA

Standby Power(50HZ)

460KW/575KVA


Ø Standard Configuration

 Engine(Sanchai SCTAA19-G5)

 Radiator 50°Cmax, fans are driven by belt, with safety guard

 24V charge alternator

 Alternator: single bearing alternator IP23, insulation class H/H

 Absorber

 Dry type air filter, fuel filter, oil filter

 Main line circuit breaker

 Standard control panel

 Two12V batteries, rack and cable

 Ripple flex exhaust pipe, exhaust siphon, flange, muffler

  User manual


ØEngine Data


1. Basic parameter

Engine Model

CUMMINS KTAA19-G5

Engine Features

In-line, 6 Cylinders, Four-stroke

Rate Power

500KW /1500rpm

Standby Power

550KW /1500rpm

Displacement

18.9L

Bore*Stroke

159*159 mm

Compression Ratio

13.5:1

Mode of Speed Regulation

Electronic

2. Exhaust Air System

Exhaust air capacity

1992 L/s

Exhaust air temperature

490℃

Max. exhaust back pressure

10kPa

3. Air Intake System

Air Intake Type

Turbocharged, Water-Air cooling

Max. Air Intake Pressure

6.23kPa

Air Combustion Capacity

750 L/s

Air flow

10800 L/s

4. Fuel System

Fuel Consumption

206g/KW.h,100.6L/h (100% loading)

5. Lubrication System

Oil Capacity

50 L

Oil Consumption

≤4g/KW.h

Oil Pan Capacity

32~38 L

Rated Speed Oil Pressure

345- 483kPa

6. Cooling System

Cooling Type

Closed Water-Cooling

Total Cooling Liquid Capacity

116.5 L

Thermostat Working Temperature

82-93℃

Max. Water Temperature

104 ℃


Ø Alternator Data


Model and number

Stamford HCI 544D

Number of Phase

3

Connecting Type

3 Phase and 4 Wires, “Y” type connecting

Number of Bearing

1

Power Factor

0.8

Protection Grade

IP23

Altitude

≤1000m

Exciter Type

Brushless, self-exciting

Insulation Class,

Temperature Rise

H/H

Telephone Influence Factor (TIF)

<50

THF

<2%

Alternator Capacity

575KVA

Alternator Efficiencies

94.9%


How to properly replace the diesel generator oil?

1. Place the generator set in a plane and start the engine for a few minutes to increase the temperature of the oil and then stop the engine.

2. Remove the oil-filled bolt (ie the oil gauge).

3. Place an oil basin under the engine and remove the oil drain screw. The oil can be drained from the crankcase.

4. Check the oil drain screw, seal ring and rubber band. If it is damaged, please replace it immediately.

5. Reinstall the oil screws and tighten them.

6. Lower the oil to the upper position of the grid of the oil gauge.