Home > Product > Generator Sets > Diesel Generator Sets

Cummins 80kw Silent Gensets

Cummins Diesel Genset SCDG-80 Ø Standard Configuration  Engine(Cummins 6BT5.9-G2 )  Radiator 50℃ max, fans are driven by belt, with safety guard  24V charge alternator  Alternator: single bearing alternator IP23, insulation class H/H  Absorber  Dry type air filter, fuel filter, oil filter...

Send InquiryChat Now
Product Details

Cummins Diesel Genset SCDG-80


Code

SCDG-80

Rated Power(50HZ)

80KW/100KVA

Standby Power(50HZ)

87KW/109KVA


Ø Standard Configuration

 Engine(Cummins 6BT5.9-G2 )

 Radiator 50℃ max, fans are driven by belt, with safety guard

 24V charge alternator

 Alternator: single bearing alternator IP23, insulation class H/H

 Absorber

 Dry type air filter, fuel filter, oil filter

 Main line circuit breaker

 Standard control panel

 Two12V batteries, rack and cable

 Ripple flex exhaust pipe, exhaust siphon, flange, muffler

 User manual


Prime Power (PRP): Prime power is available for an unlimited number of annual hours in variable load application, in accordance with GB/T2820-97(eqvISO8528); A 10% overload capability is available for a period of 1 hour within a 12-hour period of operation.

Standby Power Rating (ESP): The standby power rating is applicable for supplying emergency power for the duration of a utility power interruption. No overload, utility parallel or negotiated outage operation capability is available at this rating.

Ø Engine Data


1. Basic parameter

Engine Model

Cummins 6BT5.9-G2

Engine Features

In-line, 6 Cylinders, Four-stroke

Rated Power

83KW /1500rpm

Standby Power

92KW /1500rpm

Displacement

5.9L

Bore*Stroke

102*120 mm

Compression Ratio

17.3:1

Mode of Speed Regulation

Electronic

Net Weight

425 KG

Over Dimension

1110*750*988 mm

2. Exhaust Air System

Exhaust air capacity

16.8 m?/min

Exhaust air temperature

565 ℃

Max. exhaust back pressure

10 kPa

3. Air Intake System

Air Intake Type

Turbocharged

Max. Air Intake Pressure

6.1 kPa

Air Combustion Capacity

6.5 m³/min

Air flow

158 m³/min

4. Fuel System

Fuel Consumption

214g.kWh or 22.3L/h (100% loading)

5. Lubrication System

Oil Capacity

16.4 L

Oil Consumption

≤4g/KW.h

Oil Pan Capacity

12.3-14.2 L

Rated Speed Oil Pressure

345 kPa

6. Cooling System

Cooling Type

Closed Water-Cooling

Total Cooling Liquid Capacity

27 L

Thermostat Working Temperature

82-95 ℃

Max. Water Temperature

104 ℃


Ø Alternator Data


Brand and model:

Stamford UCI274C

Number of Phase

3

Connecting Type

3 Phase and 4 Wires, “Y” type connecting

Number of Bearing

1

Power Factor

0.8

Protection Grade

IP23

Altitude

≤1000m

Exciter Type

Brushless, self-exciting

Insulation Class,

Temperature Rise

H/H

Telephone Influence Factor (TIF)

<50

THF

<2%

Alternator Capacity

100KVA

Alternator Efficiencies

90.3%


Voltage Regulation.png



Hot Tags: cummins 80kw silent gensets, manufacturers, suppliers, factory, customized, cheap, buy discount, low price
Related Products